The cooling only stays fair and efficient if the plant behind it stays healthy. Meezan proactively maintains every asset — chillers, pumps, AHUs, FCUs — from one window, with 24/7/365 support.

One window

Every asset, one place.

Health, service history and the next scheduled visit for the whole plant — live, and tied to the same meter data that drives your bills.

meezan.cloud / care · Marina Tower A
Asset
Health
Next service
Status
Chiller 1 500 TR · screw
in 21 days
Healthy
Chiller 2 500 TR · screw
this week
Service due
Primary pump set 3 × CHW pumps
in 40 days
Healthy
AHU-3 Level 12 · fresh air
action needed
Filter alert
FCU network 250 units
rolling
Healthy
Proactive alerts

We catch it before it breaks.

Meezan watches the same live data it meters, and raises a clear, actionable alert the moment a reading drifts out of range — so an operator knows exactly what to check, and where, before comfort or the plant is at risk.

meezan.cloud / care · alerts · Marina Tower A
Critical
Low ΔT alarm · Chiller 2
Chilled-water ΔT has collapsed — plant is running but delivering little useful cooling.
Check: CHW flow, strainers and 3-way valves — likely low flow or bypass.
ΔT 3.1 °C
target ≥ 5.5 °C
Warning
Low differential pressure · CHW Pump 1
Pump is running but head has dropped — suspect impeller wear, air lock or a throttled valve.
Check: pump, suction strainer and discharge valve position.
ΔP 0.4 bar
expected ~1.8 bar
Critical
High CO₂ · Level 14 return air
Indoor air-quality CO₂ well above setpoint — fresh-air supply is likely insufficient.
Check: AHU-3 fresh-air damper actuator and supply fan.
1,180 ppm
limit 1,000 ppm
Warning
Condenser approach rising · Chiller 1
Condenser approach temperature is climbing — an early sign of tube fouling or scaling.
Check: schedule condenser tube clean; review water treatment.
approach 2.9 °C
clean < 1.5 °C
Warning
High refrigerant superheat · Chiller 3
Suction superheat trending high — possible low charge or expansion-valve issue.
Check: leak-test circuit; verify EXV operation and charge.
SH 14 K
normal 8–10 K
Info
Filter differential high · AHU-3
Filter pressure drop is near the change-out threshold.
Plan: replace filters at the next scheduled visit.
ΔP 240 Pa
change at 250 Pa
Digital service locker

Every service, on record — forever.

No more lost paper job sheets. Every visit is logged against the asset, with site photos, readings and a signed report — searchable years later for warranty, audits and building handover.

All assetsChillersPumpsAHUsFCUs
12 Jun 2026Chiller 1 service
Chiller 1 · Quarterly PPM
500 TR screw · condenser clean, oil sample, safeties tested
A. Rahman · Sifr EnergyView report →
28 May 2026CHW pump set service
CHW Pump Set · Quarterly PPM
3 × pumps · seals, bearings, alignment & ΔP verified
M. Farouk · Sifr EnergyView report →
15 May 2026AHU-3 filter and coil clean
AHU-3 · Filter & coil clean
Level 12 fresh air · filters replaced, coil washed, fan checked
S. Kumar · Sifr EnergyView report →
30 Apr 2026Chiller 2 leak test and top-up
Chiller 2 · Leak test & top-up
500 TR screw · refrigerant leak test, charge corrected
A. Rahman · Sifr EnergyView report →
2 Apr 2026AHU-7 fan belt and bearing
AHU-7 · Fan belt & bearing
Level 20 · drive belt renewed, bearings greased
S. Kumar · Sifr EnergyView report →
20 Mar 2026CHW Pump 2 seal replacement
CHW Pump 2 · Seal replacement
Mechanical seal renewed · test-run & ΔP confirmed
M. Farouk · Sifr EnergyView report →
Inside every record

A complete, signed service report.

Full operating readings, checks, findings and recommendations — Meezan-branded and captured digitally on site, ready to export as a PDF.

Chiller Service Report
Preventive maintenance visit · Meezan Care
Report #MZ-SR-24-0612
Date 12 Jun 2026
Visit: Quarterly PPM
SiteMarina Tower A
ClientTower A Owners’ Assoc.
EquipmentWater-cooled screw
Serial no.30XW-500-2291
RefrigerantR-134a
Capacity500 TR
Run hours18,420 h
TechnicianA. Rahman
Water side & electrical
Evap. entering CHW12.2 °CNormal
Evap. leaving CHW6.7 °CNormal
Chilled-water ΔT5.5 KNormal
Cond. entering CW32.1 °CNormal
Cond. leaving CW37.0 °CNormal
Condenser ΔT4.9 KNormal
Voltage L1/L2/L3401/399/402 VNormal
Current L1/L2/L3486/490/483 ANormal
Power input338 kWNormal
Efficiency0.68 kW/TRNormal
Refrigerant circuit
Evaporator pressure3.2 barNormal
Evap. saturation temp5.0 °CNormal
Suction temp13.5 °CNormal
Suction superheat8.5 KNormal
Condenser pressure9.6 barNormal
Cond. saturation temp40.0 °CWatch
Discharge temp68 °CNormal
Subcooling6.0 KNormal
Oil pressure2.4 barNormal
Condenser approach3.0 KWatch
Checks performed
Oil level & pressure
Oil sample for analysis
Compressor vibration
Leak test (0 ppm)
Safety cut-outs tested
Condenser tubes inspected
Strainers cleaned
Water treatment verified
Controls & alarms reviewed
Electrical terminals torqued
Observations & actions

Condenser saturation temperature and approach trending high — early tube fouling observed. Tubes brushed and flushed on site; approach improved to 2.4 K on retest. Oil sample sent to lab. All safeties tested and passed; chiller returned to normal operation.

Recommendations

Schedule condenser eddy-current tube test at next annual overhaul. Maintain condenser-water treatment dosing. Continue monitoring approach via Meezan alerts.

TechnicianA. Rahman
Reviewed byPlant Engineer
Next service12 Sep 2026
How Care works

Proactive, not reactive.

Because we already read every meter, we spot problems before they become breakdowns.

Condition-based

Live meter and sensor data flags drift in performance early — so we service what needs it, when it needs it.

Scheduled & tracked

Planned preventive maintenance for chillers, pumps, AHUs and FCUs — every visit logged against the asset.

One accountable team

The same team that meters and optimizes your plant maintains it — no finger-pointing between vendors.

Always available

24/7/365 emergency support.

Cooling can’t wait in a UAE summer. If something fails, our team responds around the clock — every day of the year — to keep residents comfortable and assets safe.