The cooling only stays fair and efficient if the plant behind it stays healthy. Meezan proactively maintains every asset — chillers, pumps, AHUs, FCUs — from one window, with 24/7/365 support.
Health, service history and the next scheduled visit for the whole plant — live, and tied to the same meter data that drives your bills.
Meezan watches the same live data it meters, and raises a clear, actionable alert the moment a reading drifts out of range — so an operator knows exactly what to check, and where, before comfort or the plant is at risk.
No more lost paper job sheets. Every visit is logged against the asset, with site photos, readings and a signed report — searchable years later for warranty, audits and building handover.






Full operating readings, checks, findings and recommendations — Meezan-branded and captured digitally on site, ready to export as a PDF.
| Evap. entering CHW | 12.2 °C | Normal |
| Evap. leaving CHW | 6.7 °C | Normal |
| Chilled-water ΔT | 5.5 K | Normal |
| Cond. entering CW | 32.1 °C | Normal |
| Cond. leaving CW | 37.0 °C | Normal |
| Condenser ΔT | 4.9 K | Normal |
| Voltage L1/L2/L3 | 401/399/402 V | Normal |
| Current L1/L2/L3 | 486/490/483 A | Normal |
| Power input | 338 kW | Normal |
| Efficiency | 0.68 kW/TR | Normal |
| Evaporator pressure | 3.2 bar | Normal |
| Evap. saturation temp | 5.0 °C | Normal |
| Suction temp | 13.5 °C | Normal |
| Suction superheat | 8.5 K | Normal |
| Condenser pressure | 9.6 bar | Normal |
| Cond. saturation temp | 40.0 °C | Watch |
| Discharge temp | 68 °C | Normal |
| Subcooling | 6.0 K | Normal |
| Oil pressure | 2.4 bar | Normal |
| Condenser approach | 3.0 K | Watch |
Condenser saturation temperature and approach trending high — early tube fouling observed. Tubes brushed and flushed on site; approach improved to 2.4 K on retest. Oil sample sent to lab. All safeties tested and passed; chiller returned to normal operation.
Schedule condenser eddy-current tube test at next annual overhaul. Maintain condenser-water treatment dosing. Continue monitoring approach via Meezan alerts.
Because we already read every meter, we spot problems before they become breakdowns.
Live meter and sensor data flags drift in performance early — so we service what needs it, when it needs it.
Planned preventive maintenance for chillers, pumps, AHUs and FCUs — every visit logged against the asset.
The same team that meters and optimizes your plant maintains it — no finger-pointing between vendors.
Cooling can’t wait in a UAE summer. If something fails, our team responds around the clock — every day of the year — to keep residents comfortable and assets safe.
Ask about SLAs →